High voltage tester in Talgo > SPAIN
They are testing the 25kVAC HV line of trains and bought DT2-75-200-Sk-P (75kV AC, 200 mA high voltage tester).
In order to proceed to the test, they remove the locomotives and then have access to the HV line of 1 car.
The test is made at 3 times the voltage of the line, which means 75 kV AC, according to the EN50353, chapter 8.2.2 and IEC-60077-1 chapter 9.3.3.3 standards.
http://www.talgo.com/
|
 |
 |