Product description : This box is dedicated to calibrate insulation and hipot function (also high voltage test or flash test), for our 50 VA testers.
Product details :
This box includes the following components :
INSULATION :
• 100 KΩ 1% 500Vdc Max
• 10 MΩ 1% 500Vdc Max
• 1 GΩ 1% 500Vdc Max
• 100 GΩ 1% 500Vdc Max
• 1 TΩ 5% 500Vdc Max
All the resistors inside the box are standard resistors and are delivered with a measurement certificate.
HIPOT :
• 1 High Voltage divider 1/10000 – maximum voltage : 6 kV DC / 5 kV AC
The divider has to be associated to a voltmeter with an input impedance of 10 MΩ.
• 100 KΩ 5 kV AC Max. 2%
• 1 MΩ 5 kV AC / 6 kV dc Max. 1%
• 10 MΩ 5 kV AC / 6 kV DC Max. 1%
Resistors for leakage current measurement calibration are not standard resistors. It means they have to be associated to a milliammeter that IS a standard equipment.